Downloads
Other Areas of Interest

Image

 

Image 

Blade Profiler Wind Tunnel Tests ATCA Airflow Impedance 

The Blade Profiler is a wind tunnel specifically designed to mimic an ATCA slot or shelf and measure the  impedance presented by the blade. The Blade Profiler has a series of airflow sensors that measure the linear flow distributed across the channel and the pressure drop across the blade. The system is provided with PC software that is used to vary the fan speed and generate multiple airflow levels. The PC application then determines the flow impedance by measuring the airflow and pressure drop.


The flow distribution across the blade is measured by the array of sensors and the airflow levels seen in the quadrants are plotted. The Blade Profiler gives the blade designer the ability to evaluate component placement to address airflow blockage and heat dissipation.

Degree Controls also offers various testing services through our IQS Division, located in Marlboro, Massachusetts.  These services include:

 

 

 
 
© 2008 Degree Controls, Inc. Site Map